Quantcast
Channel: Brocade Communities : Message List - Fibre Channel (SAN)
Viewing all 1133 articles
Browse latest View live

Re: can anyone explain the detailed reasons for 'too long' errors?

$
0
0
OK. The 8Gb/s SFPs are Brocade 57-1000117-01 and the 4Gb/s SFPs are Brocade 57-1000013-01 The 8Gb/s connect to the storage at 8Gb/s fixed and the 4Gb/s connect to the Ciena at 1Gb/s fixed The errors are occurring on the 1Gb/s links. Last night we upped

Re: can anyone explain the detailed reasons for 'too long' errors?

$
0
0
now you know why I ask about the SFP you use.

Re: Firmwaredownload failed Out of disk space....

$
0
0
Thank you felipon! After running the command I saw that var/logs was quite big, and in it there was a big txt-file from 15sep 2010 ag_decs.txt I deleted that and df showed 75% used on mnt and the firmwareupgrade worked

Brocade SilkWorm 4024_interface disabled - how to enable it

$
0
0
Hello Everyone.   I have bought Brocade  4Gb San Switch SilkWorm 4024 on ebay and I can't manage it using ILO of C7000. When I want to clik on Menagment url  (IP: 10.94.26.201) of this san switch  I get the message INTERFACE

Re: Brocade SilkWorm 4024_interface disabled - how to enable it

$
0
0
Hey,   http://community.brocade.com/thread/3142?start=0&tstart=0   you could try one of those commands.   configure and then enable http in there would be the first to try.

Re: Brocade SilkWorm 4024_interface disabled - how to enable it

$
0
0
so , I have to type command "configure" in CLI when I log on Brocade 4Gb SAN Switch - isn't it?

Re: Brocade SilkWorm 4024_interface disabled - how to enable it

portloginshow - Device not present

$
0
0
I have a AIX server with HBA connected to a switch port. Switch port shows online and Healthy. But, when i use portloginshow it throws me below error. I also saw lot of link errors in the server end.   SWITCH:FID100:admin> portloginshow 2/27

The factory has collapsed after the Switch, which had previously been turned off.

$
0
0
The factory consists of five switch modules (version 6.2.2.d at all, 200e 2040 model) 4020 was some time off, at which time the factory was changed, introducing new zone and alies. After switching on the 4020 factory collapsed. Time to deal was not,

Brocade M6505 is on NO_Sigdet state

$
0
0
I cannot map server to any port in both AG mode and native mode because port status show No_SigDet. How can I solve it. I already install server module and driver of fabric card on OS. Port of server still show status No_SigDet. It's not Online status.

Re: Brocade M6505 is on NO_Sigdet state

$
0
0
show as you use cu = Copper, SFP+ Direct Attached Cable.   I've a list here, and such cable are NOT Qualified for 65xx.   otherwise post please the exact SFP part Number -  "sfpshow" command give details about inserted SFP I'll check if

Re: Brocade M6505 is on NO_Sigdet state

$
0
0
I note another thing, is this a Blade Switch ?

Re: Brocade SilkWorm 4024_interface disabled - how to enable it

$
0
0
OK I have attached some screenshots to let you guys better understand what I mean. So when I try to click on Menagment URL (192.168.1.11 of SANSwitch I get this message   any suggestion how to enable it ? (Interface 192.168.1.9 is IP my eth0

Re: Brocade SilkWorm 4024_interface disabled - how to enable it

$
0
0
I'm not familiarly with such HP Blade / Chassis systems, however I don't think this is as behavior with not started or disabled services between the "configure" commands mentioned in the other Thread.   That show to me "The interface has been

Re: The factory has collapsed after the Switch, which had previously been turned off.

$
0
0
no, that's not good! the worst thing that should have happened is fabric segmentation, which means that the switch that was just powered on would be denied to join the fabric. the rest of the fabric should normally stay on, up and running.

Re: Brocade M6505 is on NO_Sigdet state

$
0
0
Yes. This is Blade Switch for Dell M1000e Blade Enclosure with QME2622. Is this hardware compatible problem?

Re: Brocade SilkWorm 4024_interface disabled - how to enable it

$
0
0
ok , I solved it. For others:   command:   Ipfilter   and then use parameters with command "ipfilter" for example :   ipfilter --show   and you can see port 80 is permit or deny.   then you have to change 80 for

Re: Brocade M6505 is on NO_Sigdet state

$
0
0
---> Is this hardware compatible problem?   No. All I/O Blade have internally Copper Port, so please ignore my preview Post, I refer here to Standalone 65xx Switches.   Usually this error indicated the Port is disconnected or unplugged, or

Replacing two DS-4100 switches with two DS-5100B switches help.

$
0
0
I'm reaching out for assistance regarding the replacement of two EMC Branded Brocade Departmental Switches DS-4100's with two new DS-5100B switches. Is anyone aware of an actual procedure that is specific to this type of upgrade? Both switches are the

Re: The factory has collapsed after the Switch, which had previously been turned off.

$
0
0
That is, in any case, switch, which included not pick up the new modified configuration of the factory and normally correctly work? Switch settings must be reset and re-do his party to the factory?
Viewing all 1133 articles
Browse latest View live


Latest Images